Written by Administrator
|
|
Monday, 23 February 2009 20:36 |
- Section capacity checking tools comunicate with Robot and automaticaly load forces from a native RSA file.
- Forces can be also introduced using xml open file format
- Altiscad Intellishape performs capacity diagram comparison
- Within the Capacity Check window, the user has opportunity to check the cross section according to the data provided by an analysis software. The N-Mx-My verification is made, showing the user when the forces are inside or outside the diagram boundaries.
- Other factors are also available:
ω, (the ratio between the capacity moment and the effective moment) ξ (the relative height of the compressed area).
Sigma in cross section
|
|
Last Updated on Tuesday, 24 February 2009 19:30 |